New Year Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 70percent

VMware 2V0-15.25 VMware Certified Professional - VMware Cloud Foundation 9.0 Support Exam Practice Test

Demo: 18 questions
Total 60 questions

VMware Certified Professional - VMware Cloud Foundation 9.0 Support Questions and Answers

Question 1

An administrator is managing a VMware Cloud Foundation (VCF) environment. They receive a request from the developers to enable vDefend - Distributed Firewall. However, they noticed It cannot be enabled due to a missing license.

Where must the new license be applied?

Options:

A.

SDDC Manager.

B.

NSX Manager.

C.

VCF Automation.

D.

VCF Operations.

Question 2

An administrator wants to expand a VMware vSAN cluster in a workload domain by adding an unassigned host from the vSphere client. However, at the Host Selection screen no hosts are available and the following message displayed:

No unassigned hosts available with storage type VSAN. Commission hosts with physical NICs 0 & 1 to Add Host from UI.

How can the administrator commission hosts?

Options:

A.

From the vSphere client by navigating to Supervisor Management.

B.

From VCF Operations by navigating to Fleet Management.

C.

From the SDDC manager by navigating to Workload Domains.

D.

From the vSphere client by navigating to the Global Inventory.

Question 3

An administrator has observed that the vSphere Global Inventory is only available from the management domain vCenter. The Global Inventory is not available from the workload domain's vCenter.

Why is the "Global Inventory" missing from the workload domain's vCenter?

Options:

A.

VCF SSO and vCenter Linking have not been configured.

B.

Supervisor Management has not been enabled.

C.

An inventory sync was not run following the workload domain creation.

D.

An external VIDB instance has not been configured.

Question 4

An administrator determined that the VMware NSX admin password expired on their VMware NSX Edge Transport nodes. The administrator manually resets the password in the console of each Edge Transport node.

What additional action is required to synchronize the new password in VMWare Cloud Foundation (VCF) Operations?

Options:

A.

In VCF Operations, rotate the admin password for each NSX Edge Transport node.

B.

In VCF Operations, remediate the admin password for each NSX Edge Transport node.

C.

In VCF Operations, sync the admin password for each NSX Edge Transport node.

D.

In VCF Operations, update the admin password for each NSX Edge Transport node.

Question 5

An administrator discovers that a VMware Cloud Foundation (VCF) workload domain four-node vSAN cluster is experiencing a network partition. The workload domain vCenter displays a "vSAN duster partition" warning. The performance across the cluster is degraded and the objects are showing as non-compliant.

What could be causing the network partition?

Options:

A.

IGMP snooping is disabled on the multicast group.

B.

The VLAN was changed on the physical switch port.

C.

Jumbo frames are configured on the vSphere distributed switch (VDS).

D.

The vSAN Witness service was added to the vMotion network.

Question 6

An administrator is attempting to log into the vCenter using the vSphere Client but receives an error stating "no healthy upstream" What are two possible causes for this? (Choose two.)

Options:

A.

The vpxd service is not running.

B.

The SSO Service is not running.

C.

Port 443 is not opened between the local machine and the vCenter.

D.

The administrator logged in with the root account.

E.

The vmware-rbd-watchdog service is not running.

Question 7

An administrator is tasked to add a new host to a vSphere cluster that was created with VMware vSAN Express Storage Architecture (ESA) as its principal storage in an existing workload domain.

The administrator successfully commissions the new host with a VMware vMotion only network pool but is unable to add the host to the existing cluster.

What must the administrator do to be able to complete this task?

Options:

A.

Decommission, reinstall ESX, and recommission the new host to the network pool for the existing vSAN ESA cluster.

B.

Change the network pool associated to the new host to the network pool for the existing vSAN ESA cluster.

C.

Manually configure the vSAN network on the new host within vCenter.

D.

Reconfigure the currently associated network pool with a vSAN network.

Question 8

An administrator has successfully mounted an NFS datastore as supplemental storage for a VMware Cloud Foundation (VCF) workload domain cluster. However, users report that data cannot be written to the datastore.

The administrator confirms the following:

• The NFS share is visible in the vSphere Client.

• Connectivity to the NFS server from the Virtual Machine.

What action should the administrator take next to troubleshoot the issue?

Options:

A.

Verify the NFS server is listed in the VMware Hardware Compatibility Guide.

B.

Reboot the ESX host to clear any file locks.

C.

Verify that the NFS server permissions are not set to read-only for the ESX host.

D.

Verify the MTU size configuration on the NFS VMkernel port group.

Question 9

An administrator is attempting to troubleshoot why the vSAN witness node cannot form a stretched cluster with the vSAN data nodes. The administrator can successfully ping the vSAN data node from the vSAN witness using the following command:

vmkping -I -s <1472> -d

What could be the possible cause of the issue?

Options:

A.

Port 12321 is not opened bidirectionally between all nodes.

B.

Port 443 is not opened bidirectionally between all nodes.

C.

The customer does not have any virtual machines in the vSAN Cluster.

D.

Jumbo Frames have not been enabled on the Witness Network.

Question 10

An administrator is creating an additional Organization for All Apps within VMware Cloud Foundation (VCF) Automation.

After logging into the VCF Automation Provider Management Portal UI, the administrator is only able to create new Organizations for All Apps.

What action can the administrator take to resolve the issue and complete the task?

Options:

A.

Create the new Organization for VM Apps using the VCF Automation API.

B.

Delete the existing Organization for VM Apps using the VCF Automation API.

C.

Delete any existing Organizations for All Apps from the Provider Management Portal UI.

D.

Enable the creation of new Organization for VM Apps feature in the Provider Management Portal UI.

Question 11

An administrator has been tasked with expanding an existing VMware Cloud Foundation (VCF) workload domain by adding a new cluster. The VCF fleet has the following configuration:

• Three workload domains, including the management domain are configured.

• The management domain (WLD-01) and one of the workload domains (WLD-02) are running VCF 9.0.

• The other workload domain (WLD-03) is running VCF 5.2.1 and is an isolated workload domain.

When attempting to perform the required steps using the vSphere Client UI the cluster cannot be added to the WLD-02 workload domain. What step should the administrator perform to complete the workload domain expansion?

Options:

A.

Use the SDDC Manager UI to create the cluster in WLD-02.

B.

Use the SDDC Manager API to create the cluster in WLD-03.

C.

Use the vSphere Client UI to create the cluster in WLD-03.

D.

Use the VCF Operations Fleet Manager UI to create the cluster in WLD-02.

Question 12

An administrator has successfully deployed and configured the Application Monitoring Telegraf Agent to 30 virtual machines through VMware Cloud Foundation (VCF) Operations.

After 24 hours, the administrator is alerted to the fact that no additional data has been collected since the agents were deployed on the virtual machines.

What could be the possible cause of the issue?

Options:

A.

There is a time synchronization issue between the Telegraf Agent and the Cloud Proxy.

B.

The Service Discovery Management Pack has not been configured.

C.

Application monitoring has been configured to use a single Cloud Proxy rather than a Collector Group.

D.

There is a compatibility issue between the version of Virtual Machine Hardware and VMware Tools.

Question 13

An administrator Is responsible for managing a VMware Cloud Foundation (VCF) fleet. The administrator discovers intermittent performance issues with the supplemental storage (ISCSI) connected to VCF workload domain. The administrator discovers that the (iSCSI) target is reachable from most VMware ESX hosts, but some hosts consistently experience periods of slow I/O and connection drops.

Which two actions should the administrator take to diagnose and resolve this issue? (Choose two.)

Options:

A.

Review the iSCSI target's configuration to ensure it's configured for maximum performance, including enabling CHAP authentication.

B.

Examine the iSCSI VMkernel port on all affected ESX hosts for TCP retransmissions and checksum offload errors.

C.

Update the network plugin on the ESX host to the latest version.

D.

Ensure all ESX hosts have the VMkernel port MTU set to 1500.

E.

Ensure all ESX hosts have the VMkernel port MTU set to 9000.

Question 14

An administrator is troubleshooting network connectivity issues on a VMware ESX host configured with a dedicated VMware vSAN vSphere Distributed Switch (vDS) port group. The VMware vSAN vDS port group has two physical adapters and two uplinks assigned. After a failure of the active physical adapter, the vSAN vDS connection over the vSAN network was lost.

What is the cause of the issue?

Options:

A.

The vSAN storage policies are misconfigured.

B.

VLAN tagging is not correctly configured on the vDS.

C.

A physical adapter is set to "Not Used" in the vDS configuration.

D.

The vDS failover policy does not allow fallback.

Question 15

An administrator is troubleshooting a vSAN issue. As part of the initial investigation, the following observations were identified:

• vSAN cluster capacity is decreased.

• Some virtual machine components are marked as degraded.

• Component rebuild process started automatically.

What is the cause of this issue?

Options:

A.

VM migration to another cluster is in progress.

B.

vSAN license capacity is too small.

C.

Too many virtual machines were created in the vSAN cluster.

D.

Physical disk failure.

Question 16

A VMware NSX Edge node is present in the inventory but shows "Not Ready" status In NSX Manager UI. What should the administrator check first?

Options:

A.

The NSX Edge has been added to an Edge cluster

B.

The license key in NSX Manager UI

C.

The NSX Edge node's uplink network configuration

D.

The NSX Edge node's CPU reservation

Question 17

An administrator creates a tag for a virtual machine (VM) in VMware Cloud Foundation (VCF) Operations. When assigning the tag to the virtual machine In vCenter, the tag was not found.

What is the cause of this error?

Options:

A.

The tag was not pushed to Custom Groups.

B.

The vCenter version is incorrect.

C.

The tag was not pushed to the vCenter instance.

D.

VM Tools is not installed.

Question 18

An administrator attempts to add a new user (provideradmin05) within the VMware Cloud Foundation (VCF) Automation Provider Management Portal, however provideradmin05 cannot be found for import.

The following information is provided:

• The existing VCF Fleet uses VMware Identity Broker (VIDB) for single sign-on.

• VIDB uses Active Directory as the identity provider.

• A group named VCFA_ProviderAdmins was created in Active Directory, populated with the appropriate user accounts and synchronized with VIDB.

• Five days later provideradmin05 was added to VCFA_ProviderAdmins.

What will resolve this issue?

Options:

A.

In VCF Operations, manually resync the directory.

B.

In the VCF Automation Provider Management Portal, enable the Advanced Rights Bundle Mode.

C.

In VCF Operations, disable VCF SSO for VCF Automation.

D.

In the VCF Automation Provider Management Portal, import provideradmin05 as an LDAP user.

Demo: 18 questions
Total 60 questions