International Code Council M2 Commercial Mechanical Inspector Exam Practice Test

Demo: 15 questions
Total 50 questions

Commercial Mechanical Inspector Questions and Answers

Question 1

Horizontal terminations for mechanical draft systems that are adjacent to public walkways shall be located a minimum of _____ feet above grade.

Options:

A.

7

B.

8

C.

9

D.

10

Question 2

Where located on a roof with a 5:12 slope, a level platform shall be provided along the access panel of the furnace at least _____ inches wide.

Options:

A.

[option text not fully visible in the material you sent]

B.

24

C.

30

D.

36

Question 3

Exhibit:

What hp is EF-2?

Options:

A.

1/2

B.

1

C.

1.5

D.

2

Question 4

Exhaust is required for which of the following areas?

Options:

A.

Gambling casinos

B.

Office break rooms

C.

High school locker rooms

D.

Prison guard stations

Question 5

A low-pressure steam heating boiler is a boiler furnishing a maximum steam pressure of _____ psi.

Options:

A.

[option text not fully visible in the material you sent]

B.

15

C.

[option text not fully visible in the material you sent]

D.

80

Question 6

Why are two or more sets of construction documents, engineering calculations, diagrams, and other data required to be submitted with each application for a permit?

Options:

A.

To ensure that the project is completed in a timely manner.

B.

All sets are to be retained by the code official in order to have a spare set of construction documents for use by any subcontractors.

C.

All sets of documents are to be kept by the code official, and at least one set will serve as a backup set of documents in case the other is lost or misplaced.

D.

One set will be retained by the code official, and the other will be returned to the applicant and kept on the job site for reference while construction is in progress.

Question 7

Exhibit:

CEF-5 is a ceiling exhaust fan manufactured by:

Options:

A.

G.E.

B.

Carnes

C.

Markel

D.

Nutone

Question 8

When a permit is issued, the code requires that one set of approved plans and specifications be returned to the applicant.

This set of plans and specifications shall be:

Options:

A.

kept on the building site.

B.

returned to the architect.

C.

filed with the county clerk or jurisdiction to properly record the property.

D.

retained by the applicant for at least one year after the job is finished in the event modifications are made.

Question 9

What is the minimum distance required between a combustion air opening at the exterior of a building and a lot line?

Options:

A.

2 feet

B.

3 feet

C.

8 feet

D.

10 feet

Question 10

Supports for hazardous exhaust duct shall be constructed of:

Options:

A.

plastic.

B.

fibrous material.

C.

noncombustible material.

D.

material complying with UL 181.

Question 11

All exposed gas piping shall be kept above grade a minimum of _____ inches.

Options:

A.

3.5

B.

6

C.

8.5

D.

12

Question 12

Unless listed for a greater or smaller dimension, mechanical draft venting systems shall terminate a minimum of _____ feet below an openable window.

Options:

A.

1

B.

4

C.

8

D.

12

Question 13

ERV systems shall not be installed in which of the following except:

Options:

A.

systems utilizing coil-type exchangers.

B.

common exhaust systems for clothes dryers.

C.

exhaust systems emitting corrosive materials.

D.

equipment designed to assist in the evacuation of occupants.

Question 14

The minimum rise required for a 10-foot run of vent connector is _____ inches.

Options:

A.

1-1/4

B.

1-1/2

C.

2

D.

2-1/2

Question 15

An equipment shutoff valve shall be in the same room and not more than how many feet away from the appliance?

Options:

A.

6

B.

7

C.

8

D.

9