International Code Council 93-Tall-Mass-Timber-Buildings 93-Tall-Mass-Timber-Buildings Exam Practice Test

93-Tall-Mass-Timber-Buildings Questions and Answers

Question 1

The maximum allowable height for a Group I-4 building of Type IV-B construction provided with an automatic sprinkler system in accordance with Section 903.3.1.1 is _____ ft.

Options:

A.

60

B.

120

C.

180

D.

270

Question 2

When Type X gypsum board is used as noncombustible protection over mass timber on the building ' s exterior walls, which of the following fasteners are permitted?

Options:

A.

Galvanized nails of minimum 12 Gage with a 7/16-inch head of sufficient length to penetrate the mass timber a minimum of 1 in.

B.

Galvanized nails of minimum 16 Gage with a 7/16-inch head of sufficient length to penetrate the mass timber a minimum of 1 in.

C.

Screws which comply with ASTM C 1002 (Type S, Type W, or Type G) of sufficient length to penetrate the mass timber a minimum of 3/4 in.

D.

Screws which comply with ASTM C 1002 (Type S, Type W, or Type G) of sufficient length to penetrate the mass timber a minimum of 7/8 in.

Question 3

Refer to the exhibit by clicking on the EXHIBIT button above.

If the glulam beam and CLT panels all require a fire-resistance rating of 2 hours, what is the required fire-resistance rating in hours for the structural connections between the glulam and CLT?

Options:

A.

0, since they are hidden fasteners

B.

1

C.

2

D.

3, to provide an additional safety factor

Question 4

Periodic special inspection of sealants or adhesives as specified by the International Building Code Section 703.7 shall be conducted at which of the following locations?

Options:

A.

At “joints” as defined in IBC Section 202.

B.

Where they are a required component of a tested fire-resistance-rated assembly.

C.

At abutting edges and intersections of mass timber building elements required to be fire-resistance rated.

D.

At abutting intersections of mass timber building elements and building elements of other materials where one or the other are required to be fire-resistance rated.

Question 5

Calculated mass timber fire resistance can include each of the following except:

Options:

A.

minimum prescriptive dimensions.

B.

calculated fire resistance of the wood.

C.

fire resistance of noncombustible protection.

D.

combination of calculated fire resistance of the wood and noncombustible protection.

Question 6

In Type IV-C construction, the fire-resistance rating provided by protection over a connection can be determined by which of the following?

Options:

A.

Testing the fasteners used in the assembly.

B.

Testing the protection covering the connection.

C.

Calculating the temperature rise of the structural element being protected.

D.

Calculating the temperature rise of the supported member used in the connection.

Question 7

According to UL Fire Resistance Directory, a “finish rating” is the time:

Options:

A.

assigned for gypsum board membranes in IBC Table 722.6.2(1)

B.

assigned for noncombustible protection in IBC Table 722.7.1(2)

C.

it takes the surface of wood nearest the fire but beneath the protective cover to reach a temperature rise of 250°F

D.

it takes the surface of wood nearest the fire but beneath the protective cover to reach a temperature rise of 325°F

Question 8

Each of the following is true regarding the fire-resistance rating for exterior bearing walls except:

Options:

A.

Type IV-C must be 1 hour

B.

Type IV-A must be 3 hours

C.

Type IV-B must be 2 hours

D.

Type IV-C must be 2 hours

Question 9

Refer to the figure by clicking on the EXHIBIT button above.

In Type IV-B construction, unprotected portions of mass timber as shown in the Figure is limited to an area equal to not more than what percentage of the base floor area?

Options:

A.

15%

B.

20%

C.

30%

D.

40%

Question 10

Buildings of Types IV-A, IV-B, and IV-C construction designed to be greater than six stories above grade plane shall meet which of the following requirements for fire safety practices during construction?

Options:

A.

Standpipes shall be provided in accordance with IFC Section 3313.

B.

The IFC specifically requires a portable water supply.

C.

Required exterior wall coverings on all floor levels more than 2 levels below the floor under construction, including mezzanines.

D.

At least two layers of noncombustible protection, where noncombustible protection is required for the building element, on all mass timber more than 4 stories below the uppermost floor under construction.

Question 11

In Type IV-C construction, a connection between two members of the primary structural frame supporting a floor is required to be protected to achieve a minimum fire-resistance rating of:

Options:

A.

1 hour

B.

1-1/2 hours

C.

2 hours

D.

3 hours

Question 12

Periodic special inspection of sealants or adhesives shall be conducted where sealants or adhesives are part of a mass timber building element as designated in the approved construction documents.

All of the following statements are correct in reference to sealants or adhesives in mass timber buildings except:

Options:

A.

Sealants shall meet the requirements of ASTM C920.

B.

Adhesives shall meet the requirements of ASTM D3498.

C.

Special inspection of mass timber sealing requirements also apply to joints.

D.

Sealants at abutting edges and intersection of mass timber buildings need periodic inspections.

Question 13

Refer to the figure by clicking on the EXHIBIT button above.

In Type IV-B construction, based on a 900 sq. ft. floor area, a 30 ' room width, and a 12 in. x 18 in. beam as shown in the Figure, the maximum length of the unprotected portion of the mass timber ceiling (dimension X) is _____ feet.

Options:

A.

2

B.

4

C.

6

D.

8

Question 14

In mass timber construction of Type IV-B, each of the following is suitable for use as fireblocking except:

Options:

A.

mineral wool.

B.

one-half-inch gypsum board.

C.

7/16-inch wood structural panels.

D.

mass timber complying with IBC Section 2304.11.

Question 15

Refer to the exhibit by clicking on the EXHIBIT button above.

In the detail shown, if the connections at the glulam beam and the steel plate required a fire-resistance rating of one (1) hour and the wood cover is designed per AWC Technical Report 10 to provide the entire one (1) hour of protection, the minimum required thickness for the wood block member providing protection for the bolt connections is _____ inches.

Options:

A.

1.5

B.

1.75

C.

2

D.

3

Question 16

Given: A building of Type IV-B construction is designed to be greater than six stories above grade plane.

At least one layer of required noncombustible protection shall be installed on all of the following building elements except _____ on all floor levels more than four levels below active mass timber construction before erecting additional floor levels during construction.

Options:

A.

mezzanines

B.

shafts and vertical exit enclosures

C.

floors as required by IBC Section 602.4

D.

wall and ceilings as required by IBC Section 602.4

Question 17

The fire-resistance of a protected mass timber assembly is equivalent to the fire resistance time of the:

Options:

A.

mass timber itself.

B.

noncombustible protection.

C.

mass timber itself plus the finish rating time of the noncombustible protection.

D.

mass timber itself plus the added contribution time attributable to the noncombustible protection.

Question 18

Each of the following is true regarding the fire-resistance rating for exterior bearing walls except:

Options:

A.

Type IV-C must be 1 hour

B.

Type IV-A must be 3 hours

C.

Type IV-B must be 2 hours

D.

Type IV-C must be 2 hours

Question 19

Proprietary nails can be used by referencing which ICC-ES Evaluation Report?

Options:

A.

ESR-1002

B.

ESR-1137

C.

ESR-1539

D.

ESR-1722

Question 20

One code-recognized method for calculating the fire-resistance rating of exposed wood members and decking is:

Options:

A.

ACI 216.1

B.

TMS 0216

C.

ASCE 29 Chapter 5

D.

AWS NDS Chapter 16

Question 21

In mass timber construction of Type IV-C, the fire-resistance ratings of bearing walls are permitted to be reduced by _____ where supporting a roof only.

Options:

A.

30-minutes

B.

45-minutes

C.

1-hour

D.

2-hours

Question 22

Mass timber is allowed in which of the following International Building Code Construction Types?

Options:

A.

Types I, II, and IV only

B.

Types III and IV only

C.

Types IV and V only

D.

Types I, II, III, IV, and V

Question 23

Which of the following is true regarding fire-resistance rating protection provided by noncombustible covering material?

Options:

A.

1/2 in. gypsum board provides 30 minutes

B.

1/2 in. Type X gypsum board provides 40 minutes

C.

5/8 in. gypsum board provides 40 minutes

D.

5/8 in. Type X gypsum board provides 40 minutes

Question 24

Which of the following is true regarding Type IV-B unprotected portions of mass timber ceilings and walls?

Options:

A.

All of the mass timber may be exposed.

B.

None of the mass timber may be exposed.

C.

20% of the floor area of the ceilings and 40% of the floor area of the walls may be exposed under certain conditions.

D.

40% of the floor area of the ceilings and 20% of the floor area of the walls may be exposed under certain conditions.