The maximum allowable height for a Group I-4 building of Type IV-B construction provided with an automatic sprinkler system in accordance with Section 903.3.1.1 is _____ ft.
When Type X gypsum board is used as noncombustible protection over mass timber on the building ' s exterior walls, which of the following fasteners are permitted?
Refer to the exhibit by clicking on the EXHIBIT button above.

If the glulam beam and CLT panels all require a fire-resistance rating of 2 hours, what is the required fire-resistance rating in hours for the structural connections between the glulam and CLT?
Periodic special inspection of sealants or adhesives as specified by the International Building Code Section 703.7 shall be conducted at which of the following locations?
Calculated mass timber fire resistance can include each of the following except:
In Type IV-C construction, the fire-resistance rating provided by protection over a connection can be determined by which of the following?
According to UL Fire Resistance Directory, a “finish rating” is the time:
Each of the following is true regarding the fire-resistance rating for exterior bearing walls except:
Refer to the figure by clicking on the EXHIBIT button above.


In Type IV-B construction, unprotected portions of mass timber as shown in the Figure is limited to an area equal to not more than what percentage of the base floor area?
Buildings of Types IV-A, IV-B, and IV-C construction designed to be greater than six stories above grade plane shall meet which of the following requirements for fire safety practices during construction?
In Type IV-C construction, a connection between two members of the primary structural frame supporting a floor is required to be protected to achieve a minimum fire-resistance rating of:
Periodic special inspection of sealants or adhesives shall be conducted where sealants or adhesives are part of a mass timber building element as designated in the approved construction documents.
All of the following statements are correct in reference to sealants or adhesives in mass timber buildings except:
Refer to the figure by clicking on the EXHIBIT button above.


In Type IV-B construction, based on a 900 sq. ft. floor area, a 30 ' room width, and a 12 in. x 18 in. beam as shown in the Figure, the maximum length of the unprotected portion of the mass timber ceiling (dimension X) is _____ feet.
In mass timber construction of Type IV-B, each of the following is suitable for use as fireblocking except:
Refer to the exhibit by clicking on the EXHIBIT button above.

In the detail shown, if the connections at the glulam beam and the steel plate required a fire-resistance rating of one (1) hour and the wood cover is designed per AWC Technical Report 10 to provide the entire one (1) hour of protection, the minimum required thickness for the wood block member providing protection for the bolt connections is _____ inches.
Given: A building of Type IV-B construction is designed to be greater than six stories above grade plane.
At least one layer of required noncombustible protection shall be installed on all of the following building elements except _____ on all floor levels more than four levels below active mass timber construction before erecting additional floor levels during construction.
The fire-resistance of a protected mass timber assembly is equivalent to the fire resistance time of the:
Each of the following is true regarding the fire-resistance rating for exterior bearing walls except:
Proprietary nails can be used by referencing which ICC-ES Evaluation Report?
One code-recognized method for calculating the fire-resistance rating of exposed wood members and decking is:
In mass timber construction of Type IV-C, the fire-resistance ratings of bearing walls are permitted to be reduced by _____ where supporting a roof only.
Mass timber is allowed in which of the following International Building Code Construction Types?
Which of the following is true regarding fire-resistance rating protection provided by noncombustible covering material?
Which of the following is true regarding Type IV-B unprotected portions of mass timber ceilings and walls?