Spring Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 70percent

Huawei H13-624_V5.5 HCIP-Storage V5.5 Exam Practice Test

Demo: 37 questions
Total 125 questions

HCIP-Storage V5.5 Questions and Answers

Question 1

In Huawei container storage solution, CSI is short for Container Storage Interface. Which of the following statements is false about Huawei CSI?

Options:

A.

CSI Driver developed by Huawei is mainly used to implement the call initiated by sidecar on Huawei storage.

B.

Huawei storage and Huawei CSI driver need to communicate with each other through RESTful to provide NAS/SAN storage resources.

C.

CSI Controller runs independently on a worker node on the Pod in StatefulSet mode and is used to interact with the storage and create and delete resources on the storage side.

D.

CSI Node runs on each worker node of Kubernetes on the Pod in DaemonSet mode and can be used to mount and unmount related storage resources.

Question 2

Huawei flash storage supports HyperReplication, which is mainly used in data disaster recovery and backup scenarios. Which of the following statements are true about this feature?

Options:

A.

Secondary resource protection refers to the process of suspending the remote replication relationship between the primary and secondary volumes.

B.

A pair refers to the data replication relationship between the primary and secondary LUNs. When the pair running status is "Normal", data is successfully synchronized between the primary and secondary LUNs.

C.

A consistency group is a collection of pairs that have a service relationship with each other.

D.

Synchronization is the process of copying data from a primary volume to a secondary volume.

Question 3

The_____feature provided by the OceanStor Pacific series storage system supports OPS and bandwidth upper limit control based on namespaces, accounts, and client IP addresses.

Options:

Question 4

When delivering a Huawei flash storage project, an engineer introduced the SAN/NAS Integrated architecture to the customer. Which of the following statements Is false about the architecture?

Options:

A.

The protocol layer is responsible for protocol parsing and permission management. SAN and NAS are two sets of semantic logic. Therefore, different service entry components are used.

B.

The space management layer uses the active-active high reliability mode to provide reliable data protection capabilities based on actual service scenarios of customers.

C.

The software architecture consists of the following layers from top to bottom: protocol, data service, cache, file and block space management, and storage pool.

D.

At the protocol layer, NFS/CIFS supports direct TCP offload engine (DT06), while ISCSI does not.

Question 5

To analyze disk performance, we can first use tools (such as free, top, vmstat, and pidstat) that support many indicators, and then determine the I/O source and analyze the file system and process I/Os.

Options:

A.

TRUE

B.

FALSE

Question 6

The backup and archiving scenario mainly involves sequential read of large I/Os, where there are more read I/Os than write I/Os and hot data areas are obvious. The service characteristics of this scenario are the same as those of the database OLAP scenario.

Options:

A.

TRUE

B.

FALSE

Question 7

A financial customer purchases a Huawei OceanStor Pacific 9950 storage device for service deployment. Engineers have configured basic block storage services on the device. During an O & M management process, an engineer needs to modify the attributes of a storage pool. Which of the following attributes will not be modified?

Options:

A.

Hot spare policy of the storage pool

B.

Storage pool name

C.

Actual location of the storage pool

D.

Capacity alarm threshold

Question 8

A school customer has purchased two Huawei flash storage devices and deployed them in different equipment rooms. To ensure data and service reliability, an engineer deploys the HyperReplication (remote replication) feature on the storage devices. After a fault recovery, the engineer needs to manually synchronize data to restore the pair relationship between the primary and secondary LUNs. What is the current running status of the remote replication pair?

Options:

A.

To be recovered

B.

Synchronizing

C.

Normal

D.

Split

Question 9

A financial customer has purchased several Huawei OceanStor Pacific 9550 storage systems. When configuring basic object services on the storage systems, an engineer discovers that the object service cannot be enabled for storage nodes. Which of the following is not a possible cause?

Options:

A.

The engineer has manually adjusted the time of the cluster nodes. As a result, the conflict handling is different.

B.

NTP synchronization is not configured for the cluster, and different NTP time sources are used.

C.

Namespaces with the same name have been created under the same account.

D.

The Network Time Protocol (NTP) clock in the storage cluster is inconsistent with the clock of the client that accesses object services.

Question 10

During routine O & M, if an engineer finds that the system disk and some interface modules of a flash storage device are faulty, the engineer can directly remove and replace the faulty parts.

Options:

A.

TRUE

B.

FALSE

Question 11

An Industry customer purchases several Huawei flash storage devices for service deployment. During an inspection, an engineer finds that some storage components are faulty and need to be removed and replaced. Which of the following statements Is true about the part removal and replacement?

Options:

A.

The interface modules and system subracks of the storage device can be replaced independently.

B.

The CPUs of the storage device cannot be replaced independently, but can be removed independently.

C.

The memory modules and system disks of the storage device can be removed and replaced independently.

D.

The coin batteries of the storage device cannot be replaced or removed.

Question 12

An industry customer has purchased a Huawei OceanStor Pacific 9950 scale-out storage device for service deployment. During an inspection of the device, the location indicator of a main storage disk module is steady yellow. What is the status of the disk module?

Options:

A.

The main storage disk module is being located.

B.

The main storage disk module is running properly.

C.

The main storage disk module is powered off.

D.

The main storage disk module is faulty or about to fail.

Question 13

A bank customer purchases several Huawei flash storage devices to store upper-layer Oracle database service data. If an Oracle database fault occurs, engineers need to collect Oracle alert log files to locate the fault. Which of the following commands cannot be used to query the alert log path?

Options:

A.

ioscan -funC disk > /home/pvlinks_disk

B.

CRS_HOME/bin/diagcollection.sh

C.

show parameter background_dump_dest

D.

db2support outpath -d db_name -c

Question 14

A financial customer purchases several Huawel OceanStor Dorado series storage devices for service deployment. During a maintenance process, an engineer needs to use DeviceManager to collect disk health analysis (DHA) logs. Which of the following is not Included in DHA logs?

Options:

A.

I/O statistics

B.

Routine disk health statistics

C.

Device latency statistics

D.

Disk life span information

Question 15

Assume a government customer purchased several Huawei scale-out storage devices for service deployment. An engineer needs to configure file services in standard protocol scenarios. Which of the following actions does not need to be performed by the engineer during the configuration?

Options:

A.

Install DPC.

B.

Create a converged storage pool.

C.

Create namespaces.

D.

Enable the file service for nodes.

Question 16

In a flash storage system, the ports of the cascading interface module or onboard cascading ports on the controller enclosure can only connect to port PI on the disk enclosure.

Options:

A.

TRUE

B.

FALSE

Question 17

An industry customer has purchased several Huawei flash storage devices for service deployment. To improve service data reliability, an engineer configures the HyperReplication feature on the storage devices. If the engineer wants to modify the properties of a remote replication pair, which of the following commands cannot be used? (Choose all that apply)

Options:

A.

change hyper_metro_pair general

B.

change hyper_metro_pair start

C.

show consistency_group general

D.

change remote_replication synchronize

Question 18

Huawei flash storage supports_____. That is, the existing storage system can be used to meet customers' Increasing requirements by continuously adding storage components.

Options:

Question 19

NVMe over Fabrics can map NVMe commands and data to multiple fabric links, including Fibre Channel, InfiniBand, RoCE v2, iWARP, and TCP.

Options:

A.

TRUE

B.

FALSE

Question 20

Similar to the alarm analysis method, the replacement method can be used to locate and rectify any type of faults for Huawei converged storage, and has no special requirement for maintenance personnel.

Options:

A.

TRUE

B.

FALSE

Question 21

Huawel OceanStor Pacific series storage supports the volume- or snapshot-based clone feature. Which of the following statements Is false about this feature?

Options:

A.

Small storage space occupation: A clone generated by the storage system is not a full physical data copy, which does not occupy large storage space.

B.

Quick generation: The storage system can generate a clone within several seconds to obtain the consistent copy of the source volume data.

C.

Lossless performance: Based on the ROW mechanism, the done write performance is equivalent to the source volume write performance.

D.

Cascading: Clones can be created based on clone volumes or snapshots of clone volumes in the storage system. A maximum of 64 cascading levels are supported.

Question 22

Huawel OceanStor Pacific series products provide object storage capabilities and support cross-site disaster recovery (DR). Which of the following statements about object storage cross-site DR is false?

Options:

A.

In cross-site DR cluster deployment mode, each site is independent. Specifically, it has an independent DeviceManager GUI and independent erasure code (EC) configuration.

B.

In backup and archiving scenarios that do not require a low latency, the redundancy mode between sites can be set to EC redundancy during cross site DR configuration.

C.

During cross-site DR configuration, if replicas are used for redundancy protection across sites, each site has complete object data.

D.

The cross-site DR of OceanStor Pacific series uses an asynchronous replication mechanism. The recovery point objective (RPO) is greater than 0, and the traffic control configuration cannot be adjusted.

Question 23

Which statements are false about software Installation of Huawei OceanStor Pacific series storage systems?

Options:

A.

To install the Distributed Parallel Client (DPC), the switch configuration is required before the installation regardless of whether the low level design (LLD)- or wizard-based installation mode is selected.

B.

To interconnect with FusionCompute during block service installation, storage and compute nodes must be deployed in converged mode, and the management nodes must be deployed in the virtualization environment.

C.

To interconnect with Huawei Cloud Stack during block service installation, storage and compute nodes must be deployed in converged mode, and the management nodes must be deployed in the virtualization environment.

D.

To install the file service in the standard protocol scenario, the switch configuration is not required throughout the entire installation process.

Question 24

A financial customer has purchased a Huawei flash storage system for service deployment. An engineer configures the HyperCDP feature on the storage system and wants to create a HyperCDP schedule. Which of the following commands can the engineer use?

Options:

A.

create hyper_cdp_schedule general

B.

add hyper_cdp_schedule fs

C.

create fs_hyper_cdp general

D.

change hyper_cdp_schedule enabled

Question 25

Assume a financial customer purchased several Huawei scale-out storage devices for deploying the video surveillance service. This service has high requirements on performance. Therefore, the cache write policy must be set to write-through for the storage devices.

Options:

A.

TRUE

B.

FALSE

Question 26

When delivering a Huawei OceanStor Pacific storage project, a Huawei engineer vigorously promoted the SmartEncryption feature of scale-out storage to customers. Which of the following statements is false about this feature?

Options:

A.

When the data is read using the DPC or NFS protocol, the SED obtains the identity authentication key from the key management server, reads and decrypts the ciphertext data, and then returns the plaintext data to the protocol layer. The protocol layer returns the plaintext data to client applications.

B.

This feature supports encrypted data write using NFS, CIFS, HDFS, or S3. Data is decrypted and read using NFS, CIFS, HDFS, or S3.

C.

The file service client can write plaintext data through the NFS/CIFS/DPC protocol.

D.

Huawei OceanStor Pacific series scale-out storage supports disk encryption. All data delivered by services is stored on self-encrypting disks (SEDs).

Question 27

The scale-out storage system supports cabinet-level security. That is, N data blocks and M parity blocks are stored in different cabinets. If M nodes or M disks are faulty, the system can still read and write data without service interruption or data loss. If M cabinets are faulty, services may be interrupted.

Options:

A.

TRUE

B.

FALSE

Question 28

When demarcating a performance issue of Huawei flash storage, engineer A finds that the latency observed on the compute side is much longer than that on the storage side. This indicates that the issue most possibly occurred on the storage, for example, the disk performance upper limit has been reached.

Options:

A.

TRUE

B.

FALSE

Question 29

Assume an Industry customer purchased a Huawel flash storage device for service deployment. After a fault occurs, an engineer needs to use the CLI to view bit error Information of front end host ports for troubleshooting. Which of the following commands cannot be used for this purpose?

Options:

A.

show coexist-forward-switch

B.

show controller io io_type=frontEnd controller_id=XX

C.

show port biLerror

D.

show host-port error

Question 30

If a performance Issue occurs in Huawei flash storage, an engineer can perform optimization operations according to the storage performance optimization process. Which of the following statements is false about the performance optimization process?

Options:

A.

In the information collection phase, the engineer needs to collect basic information about applications and data, such as the impact of application configurations on data, data size, and read/write ratio.

B.

In the test and application phase, the engineer needs to test the configurations to check whether the optimization objective is achieved. If yes, the engineer can put the system into use.

C.

In the optimization analysis phase, the engineer needs to specify the performance optimization objective, find out the performance bottleneck, and identify the parts that play a key role in Improving the system performance.

D.

In the optimization operation phase, the engineer needs to deploy DR for the service system, and needs to modify multiple configuration at a time during the optimization configuration.

Question 31

An industry customer purchased several Huawei OceanStor Pacific series scale-out storage devices for service deployment, and an engineer configured the SmartMigration feature on the storage devices. Now the engineer wants to change the split mode and migration rate of a SmartMigration task due to changes in service requirements. Which of the following SmartMigration running statuses does not allow the engineer to perform the change?

Options:

A.

Interrupted

B.

Paused

C.

Faulty

D.

Migrating

Question 32

Assume a financial customer purchases several Huawei scale-out storage devices for service deployment. Unstructured services require multiple network planes. Which statement about the network planes is false?

Options:

A.

The internal management network is used for communication between storage and management nodes, including deployment and upgrade, resource configuration, performance alarm reporting, and certificate and key update.

B.

For the file service in the Distributed Parallel Client (DPC) scenario, the back-end storage network is available for communication with compute nodes to process communication data between the DPC and Object Storage Device (OSD).

C.

The management network is used for system management and maintenance. It is connected to the customer’s management network.

D.

The service network is connected to the customer’s application system and accesses the storage through the S3, HDFS, NFS, CIFS, and POSIX interfaces.

Question 33

In Huawei flash storage, the administrator rote has full control permissions on storage devices. The administrator can power on, power off, and restart devices and create users of different roles.

Options:

A.

TRUE

B.

FALSE

Question 34

If Huawei scale-out storage software is installed in low level design (LLD) mode, engineers need to use the ________ installation and deployment tool to plan nodes, networks, and clusters and export the configuration file for subsequent installation and deployment.

Options:

Question 35

The service system needs to be backed up before performance optimization b performed on Huawei flash storage, and up to two optimization configurations can be changed at a time.

Options:

A.

TRUE

B.

FALSE

Question 36

In Huawei backup storage OceanProtect X3000, data reduction supports fixed-length (^duplication by default, but does not support variable-length (^duplication. Therefore, fixed-length ded11plication Is mainly used in the backup field.

Options:

A.

TRUE

B.

FALSE

Question 37

When learning the SmartVirtualization feature of Huawei flash storage, a new employee is not familiar with eDevLUNs and external LUNs. Which of the following statements are true about the eDevLUNs and external LUNs?

Options:

A.

An eDevLUN consists of actual data and metadata. The storage space required by metadata is provided by the heterogeneous storage system, and the physical space required by actual data is provided by the local storage system.

B.

If the administrator has not configured any value-added feature for eDevLUNs, each eDevLUN occupies small space in the storage pool of the local storage system.

C.

eDevLUNs belong to storage pools created in the local storage system.

D.

eDevLUNs can be created regardless of whether external LUNs are normal.

Demo: 37 questions
Total 125 questions