Assume a scientific research Industry customer purchased several Huavvel OceanStor Pacific series scale-out storage devices for service deployment, and an engineer has configured the file service in the Distributed Parallel Client (DPC) scenario on the storage devices. To meet high performance requirements of front end services, the engineer wants to enable the CPU performance mode for the DPC node using the CU. Which of the following commands can be used to enable the CPU performance mode?
In Huawei flash storage. If you want to apply the HyperCDP feature to a LUN, you are advised to reserve 5% to 10% of the LUN capacity in the storage pool to which the I UN belongs for storing HyperCDP object data, and configure a protection capacity threshold for the storage pool to stop creating HyperCDP objects or even automatically delete HyperCDP objects when the storage pool capacity is insufficient.
A financial customer has purchased several Huawei OceanStor Pacific 9550 storage systems. When configuring basic object services on the storage systems, an engineer discovers that the object service cannot be enabled for storage nodes. Which of the following is not a possible cause?
During routine inspection, engineers find that several faults occur on Huawei all-flash storage and need to rectify the faults. Which of the following is not a basic troubleshooting principle for storage systems?
The service system needs to be backed up before performance optimization b performed on Huawei flash storage, and up to two optimization configurations can be changed at a time.
When delivering a scale-out storage project, Huawei engineers introduced the OceanStor Pacific parallel file system service to the customer. Which of the following statements is false about the service?
During the use of Huawei flash storage, an engineer wants to calculate the valid write bandwidth of disks. Which of the following formulas can calculate disk valid write bandwidth?
An engineer wants to configure the iSCSI block service on a Huawei scale-out storage device. Which of the following operations must be performed by the engineer?
During routine inspection, an engineer of a bank finds that an interface module of a Huawei flash storage device is faulty. In this case, the engineer can directly remove and insert the interface module without any pre-operations.
Assume a bank customer purchased several Huawei flash storage devices for deploying the document Imaging service. This service mainly involves random large I/Os, more read operations than write operations, and many metadata operations, with obvious hot and cold data characteristics.
When delivering a Huawel OceanStor Pacific scale-out storage project, Huawei engineers Introduced the end-to-end load balancing capabllty supported by the scale-out storage to the customer. Which of the following statements are false about the load balancing capability?
The scale-out storage system supports cabinet-level security. That is, N data blocks and M parity blocks are stored in different cabinets. If M nodes or M disks are faulty, the system can still read and write data without service interruption or data loss. If M cabinets are faulty, services may be interrupted.
A government customer has purchased several Huawei OceanStor Pacific series storage devices. An engineer wants to install the distributed parallel client (DPC) on the storage devices. The operations before DPC installation have been completed. Now, the engineer needs to add DPC nodes. Which of the following statements are true about adding nodes?
When delivering a Huawei flash storage project, an engineer introduced the SAN/NAS Integrated architecture to the customer. Which of the following statements Is false about the architecture?
If Huawei scale-out storage software is installed in low level design (LLD) mode, engineers need to use the ________ installation and deployment tool to plan nodes, networks, and clusters and export the configuration file for subsequent installation and deployment.
When deploying a Huawei converged storage system, engineer A uses the UltraPath software. Which of the following statements are false about the load balancing algorithms of UltraPath?
Before configuring services for Huawei flash storage, you need to Initialize the system. Which statement about the initialization is false?
Assume a government office purchases a Huawel OceanStor Pacific 9550 storage device. During an Inspection, an engineer notices the IAN on motherboard (LOM) optical port Indicator on the rear panel of the device Is steady yellow. This indicates that data is being transmitted at a rate of 25 Gbit/s.
Huawel OceanStor Pacific series storage supports the volume- or snapshot-based clone feature. Which of the following statements Is false about this feature?
Assume a government office purchases several Huawei OceanStor Pacific series storage products. Which statement is false about the hardware and software deployment of the storage products?
Huawei scale-out storage provides file services using the distributed parallel client (DPC) to meet the requirements of high-performance computing (HPC) scenarios. Which of the following statements about the DPC is false?
A financial customer purchases a Huawei flash storage device for subsequent service deployment. During storage configuration, an administrator finds that LUNs mapped to an application server cannot be detected on the application server. Which of the following are possible causes of this exception?
A government customer has purchased two Huawei flash storage devices and deployed them in different data centers for running remote replication services. When a primary/secondary switchover is performed for the remote replication pair, the primary and secondary sites record the data changes. When the secondary site becomes the primary site following the primary/secondary switchover, all data will be synchronized between the primary and secondary sites.
The backup and archiving scenario mainly involves sequential read of large I/Os, where there are more read I/Os than write I/Os and hot data areas are obvious. The service characteristics of this scenario are the same as those of the database OLAP scenario.
Assume an industry customer purchased several Huawei flash storage devices for service deployment. During routine management, an engineer found that the host bus adapter (HBA) driver version of the host is outdated and the number of concurrent HBAs was insufficient. As a result, the latency on the host differs greatly from that on the storage side. Which of the following measures can the engineer take to optimize performance?
Assume a financial customer purchased multiple Huawei OceanStor Dorado 18000 storage devices to carry service data. A Fibre Channel link exception occurred in the storage environment. Which of the following are possible causes for this exception?
Assume an enterprise customer purchased several Huawei flash storage devices for service deployment. An engineer needs to configure Syslog notification on the storage system. Which of the following statements are false about configuration operations?
Routine management on Huawei flash storage systems involves power-on and power-off. Which of the following statements is false about power-on and power-off?
After purchasing a Huawei OceanStor Dorado series storage system, a customer needs to configure basic storage services in the storage system. Which of the following operations are optional in the basic service configuration?
To analyze disk performance, we can first use tools (such as free, top, vmstat, and pidstat) that support many indicators, and then determine the I/O source and analyze the file system and process I/Os.
The LUN active-active balancing feature of Huawei all flash storage Integrates the global load balancing.design. The front-end interface board evenly distributes I/Os to the target controller for load balancing.