Huawei H13-624_V5.5 HCIP-Storage V5.5 Exam Practice Test

Demo: 18 questions
Total 60 questions

HCIP-Storage V5.5 Questions and Answers

Question 1

An engineer can use multiple common management software to configure, manage, and maintain Huawei converged storage. Which of the following statements is false about the software and corresponding functions?

Options:

A.

SmartKit provides capabilities such as alarm reporting, file upload, and remote access.

B.

DeviceManager allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

C.

DME IQ enables cloud-based management, remote maintenance, automatic service request creation, and prediction and prevention, comprehensively improving customers’ O&M capabilities.

D.

The command-line interface (CLI) allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

Question 2

An Internet customer has deployed a remote replication environment based on multiple flash storage devices. During actual service running, the customer discovers that there are multiple running statuses for a remote replication pair. Which of the following statements is true about the running status of a pair?

Options:

A.

After a pair is disconnected, if the pair is deleted from the primary or secondary site, which causes configuration inconsistency between the primary and secondary sites, the pair running status changes to "To be recovered."

B.

When the pair running status is "Split," the pair relationship between the primary and secondary LUNs is interrupted (not manually).

C.

When the pair running status is "Normal," data synchronization between the primary and secondary LUNs is complete.

D.

When the pair running status is "To be synchronized," the pair relationship between the primary and secondary LUNs must be manually disconnected to meet the service requirements of a single LUN.

Question 3

A government customer has purchased two Huawei flash storage devices and deployed them in different data centers for running remote replication services. When a primary/secondary switchover is performed for the remote replication pair, the primary and secondary sites record the data changes. When the secondary site becomes the primary site following the primary/secondary switchover, all data will be synchronized between the primary and secondary sites.

Options:

A.

TRUE

B.

FALSE

Question 4

When delivering a scale-out storage project, Huawei engineers introduced the OceanStor Pacific parallel file system service to the customer. Which of the following statements is false about the service?

Options:

A.

Small I/Os are aggregated in the cache and then written to disks, achieving an ideal latency and improving the utilization of small files.

B.

Fixed-length large-granularity indexes are used to ensure sequential read/write performance of large I/Os.

C.

Large I/Os can be directly forwarded to the home node for processing, eliminating the overhead of scale-out locks and greatly reducing the read/write latency of large I/Os.

D.

In terms of I/O flow, large I/Os are written to disks in passthrough mode, improving the bandwidth capability.

Question 5

As a next-generation storage system, Huawei OceanStor Dorado series can focus on core enterprise services and meet enterprises’ service requirements. Which of the following statements are false about Huawei OceanStor Dorado series storage systems?

Options:

A.

The back-end shared interface module of OceanStor Dorado 18000 is inserted into the enclosure. The disk enclosure connected to the interface module can be accessed by controllers in the engine at the same time.

B.

Dorado V6 series and new converged storage products use the PCIe Scale-Out architecture.

C.

OceanStor Dorado 18000 uses 200 Gbit/s RDMA shared interface modules for cross-engine expansion, implementing full interconnection between 8, 12, and 16 controllers.

D.

OceanStor Dorado 18000 supports a maximum of 28 interface modules and implements intra-engine mirroring and cross-engine interconnection through the 100 Gbit/s RDMA network.

Question 6

A financial customer purchases Huawei OceanStor Pacific 9950 for service deployment. During a routine inspection, an engineer finds that a main storage disk of the device is faulty and uses SmartKit to replace it. Which of the following statements is true about replacing the disk?

Options:

A.

When removing the disk, the engineer needs to remove it from its connector, wait at least 60 seconds, and then remove the disk from the chassis.

B.

Before using SmartKit to replace the disk, the engineer needs to complete the pre-processing as prompted. After that, the engineer can continue the subsequent operations.

C.

The duration from removing the main storage disk to installing a normal one on the node cannot exceed 10 minutes. Otherwise, heat dissipation of the storage device will be affected.

D.

The interval between removing the faulty disk and inserting a normal one is at least 10 seconds. Otherwise, the disk may be damaged.

Question 7

Assume an industry customer purchased several Huawei flash storage devices for service deployment. During routine management, an engineer found that the host bus adapter (HBA) driver version of the host is outdated and the number of concurrent HBAs was insufficient. As a result, the latency on the host differs greatly from that on the storage side. Which of the following measures can the engineer take to optimize performance?

Options:

A.

Use the management software provided by the HBA vendor to query and modify the number of concurrent HBAs.

B.

Upgrade the HBA driver to the latest version.

C.

Change the load balancing algorithm of the multipathing software to min-task.

D.

Change the cache prefetch policy to constant prefetch.

Question 8

When delivering a Huawei OceanStor Pacific storage project, a Huawei engineer vigorously promoted the SmartEncryption feature of scale-out storage to customers. Which of the following statements is false about this feature?

Options:

A.

When the data is read using the DPC or NFS protocol, the SED obtains the identity authentication key from the key management server, reads and decrypts the ciphertext data, and then returns the plaintext data to the protocol layer. The protocol layer returns the plaintext data to client applications.

B.

This feature supports encrypted data write using NFS, CIFS, HDFS, or S3. Data is decrypted and read using NFS, CIFS, HDFS, or S3.

C.

The file service client can write plaintext data through the NFS/CIFS/DPC protocol.

D.

Huawei OceanStor Pacific series scale-out storage supports disk encryption. All data delivered by services is stored on self-encrypting disks (SEDs).

Question 9

During flash storage initialization, an administrator needs to change the IP address of a management network port. Which statements about the change are false?

Options:

A.

To change the IP address of the management network port on the CLI, log in to the CLI and run the "change system management_ip" command.

B.

The IP addresses of the management and maintenance network ports must be in different network segments; otherwise, there will be a route conflict.

C.

The administrator needs to apply for and activate a license before changing the IP address of the management network port.

D.

To change the IP address of the management network port on the command-line interface (CLI), the IP address of the maintenance terminal and the default IP address of the storage management network port must be in the same network segment if the administrator logs in to the system through a serial port.

Question 10

A financial customer has purchased several Huawei OceanStor Dorado series storage devices for mission-critical service deployment. SmartMigration is configured to migrate services from a source LUN to a target LUN without interrupting host services. Which of the following statements about this feature is false?

Options:

A.

The implementation of a SmartMigration task between heterogeneous storage systems depends on the LUN takeover function provided by SmartVirtualization.

B.

When configuring this feature, you must plan the capacities of the source and target LUNs. The capacity of the target LUN must be greater than or equal to that of the source LUN.

C.

When configuring this feature, you cannot use a LUN that has been mapped to an application server as the target LUN of a SmartMigration task.

D.

The higher the migration rate, the better the host service performance is. Therefore, the highest migration rate can be used when the host service load is heavy.

Question 11

A government customer has purchased several Huawei scale-out storage devices, and an engineer wants to install the distributed parallel client (DPC). When creating DPC nodes, the engineer can manually add a node by entering the service IP address of the node.

Options:

A.

TRUE

B.

FALSE

Question 12

For Huawei flash storage, a user can configure the DME IQ service for upload logs, including performance logs and disk health analysis (DHA) logs. DHA logs refer to routine run logs of disks, which contain collected disk health and I/O statistics.

Options:

A.

TRUE

B.

FALSE

Question 13

An industry customer has purchased a Huawei OceanStor Pacific 9950 scale-out storage device for service deployment. During an inspection of the device, the location indicator of a main storage disk module is steady yellow. What is the status of the disk module?

Options:

A.

The main storage disk module is being located.

B.

The main storage disk module is running properly.

C.

The main storage disk module is powered off.

D.

The main storage disk module is faulty or about to fail.

Question 14

An engineer wants to configure the iSCSI block service on a Huawei scale-out storage device. Which of the following operations must be performed by the engineer?

Options:

A.

Create a block storage pool.

B.

Configure the iSCSI service.

C.

Configure DPC share access on a client.

D.

Install DPC.

Question 15

An engineer can use the ______ tool to install software for Huawei storage systems. This tool can collect and evaluate storage compatibility information in one-stop mode and supports batch installation of the UltraPath software, improving the software installation efficiency.

Options:

Question 16

During routine inspection, engineers find that several faults occur on Huawei all-flash storage and need to rectify the faults. Which of the following is not a basic troubleshooting principle for storage systems?

Options:

A.

Analyze network alarms before NE alarms.

B.

Analyze general alarms before specific alarms.

C.

Analyze alarms of higher severities before those of lower severities.

D.

Analyze external factors before internal factors.

Question 17

Assume an enterprise customer purchased several Huawei flash storage devices for service deployment. An engineer needs to configure Syslog notification on the storage system. Which of the following statements are false about configuration operations?

Options:

A.

During the configuration, the engineer needs to configure the SNMP protocol and USM users in the storage system for receiving and querying system alarms.

B.

To view the display format of Syslog content, the engineer can run the "show notification syslog" command.

C.

To change the display format of Syslog content to CEF, the engineer can run the "change syslog-notification format_type=cef" command.

D.

If certificates and CA certificates are generated on the Syslog server, the engineer does not need to perform any operation in the storage system.

Question 18

A financial customer has purchased a Huawei OceanStor Dorado series storage system for service deployment. To ensure service data reliability, an engineer configures the HyperClone feature on the storage system. Which of the following statements about this feature are false?

Options:

A.

A source LUN and a target LUN form a HyperClone pair, and a source LUN cannot form multiple HyperClone pairs with different target LUNs.

B.

This feature provides a full copy of the source LUN’s data at the synchronization start time. Hosts can read and write the target LUN immediately, without waiting for the copy process to complete.

C.

This feature synchronizes data from the source LUN to the target LUN and can also restore data from the target LUN to the source LUN.

D.

There are significant differences between clone blocks and clone file systems. The former is implemented based on the redirect-on-write (ROW) technology, while the latter is implemented based on the copy-on-write (COW) technology.