Hitachi HH0-240 HDS CERTIFIED IMPLEMENTER - ENTRY LEVEL ENTERPRISE Exam Practice Test

Demo: 18 questions
Total 120 questions

HDS CERTIFIED IMPLEMENTER - ENTRY LEVEL ENTERPRISE Questions and Answers

Question 1

A customer has virtualized a USP behind an HUS VM. Which two actions are enabled by Universal Volume Manager? (Choose two.)

Options:

A.

Format external volumes.

B.

Disconnect external volumes.

C.

Assign internal LDEV addresses to external volumes.

D.

Migrate HUS VM volumes to the USP.

Question 2

What happens to cache data in an HUS VM when a total power cut is experienced?

Options:

A.

It is retained in cache until battery power drops to 40% then destaged to flash memory.

B.

It is immediately destaged to a pre-specified HDD.

C.

It is immediately destaged to flash memory.

D.

It is retained in cache until battery power drops to 40% then destaged to a pre-specified HDD.

Question 3

What are two effects of configuring LUN security on an HUS VM? (Choose two.)

Options:

A.

The secured LUNs will be write protected.

B.

Un-registered Open Systems hosts cannot access the data on the secured LUNs.

C.

If LUN security is applied to a particular port, only hosts with the same operating system installed can connect to that port.

D.

If LUN security is applied to a particular port, that port can only be accessed from hosts registered within this port's Host Groups.

Question 4

A customer wants to migrate data from a USP to an HUS VM. When doing so, you recommend that they virtualize the USP behind the HUS VM as external storage. Which host mode should you set on the USP?

Options:

A.

Linux

B.

External

C.

AIX

D.

Windows

Question 5

You arrive on site to work on an HUS VM system and observe that the front panel "Message" LED is on. What does this indicate?

Options:

A.

HiTrack is not configured.

B.

The SVP is in Modify mode.

C.

A SIM is pending.

D.

Remote maintenance is being performed on the system.

Question 6

A customer has deployed Hitachi Universal Replicator on their HUS VM systems. They would like to be alerted when their Recovery Point Objective (RPO) exceeds the business requirements. Which product would you recommend?

Options:

A.

Hitachi Replication Manager

B.

Hitachi Command Director

C.

Business Continuity Manager

D.

Hitachi Tuning Manager

Question 7

What is the purpose of the System Assurance Document?

Options:

A.

to ensure accurate and complete record of pre-installation data

B.

to guarantee that HDS equipment is insured during transportation

C.

to inform a channel partner that equipment is available for shipment

D.

to validate configuration changes for customers with a premium service contract

Question 8

With which two products does Hitachi Tuning Manager integrate? (Choose two.)

Options:

A.

Device Manager

B.

Protection Manager

C.

Replication Manager

D.

Tiered Storage Manager

Question 9

You need to perform an initial setup procedure on a new HUS VM system. What is required to clear the configuration data?

Options:

A.

Switch off the batteries.

B.

Set the maintenance DIP switches on the SVP.

C.

Disconnect the battery cables.

D.

Connect CE jumpers to the first MP board pair.

Question 10

What is the maximum number of SSD disks that can be installed in an HUS VM?

Options:

A.

48

B.

128

C.

256

D.

512

Question 11

How much additional Shared Memory capacity is necessary to configure ShadowImage/Volume Migration/Dynamic Provisioning in an HUS VM?

Options:

A.

0 GB

B.

2 GB

C.

4 GB

D.

8 GB

Question 12

You have replaced a part on an HUS VM. What are three mandatory steps to complete your maintenance task? (Choose three.)

Options:

A.

Complete the "Last maintenance" form inside the DKC door.

B.

Complete the corresponding SIM(s).

C.

Reboot the SVP to renew the configuration.

D.

Verify the machine status using the maintenance screen.

E.

Set the SVP application back to View Mode.

Question 13

What are two HDD types supported in the HUS VM? (Choose two.)

Options:

A.

SAS

B.

FC

C.

SSD

D.

SATA

Question 14

Which three documents must be referenced when planning a microcode exchange on an HUS VM? (Choose three.)

Options:

A.

ECN

B.

FCO Bulletins

C.

Product Alerts

D.

Maintenance Manual

E.

Microcode Exchange Reference Guide

Question 15

An HUS VM has reported a SIM indicating an external storage error. Which troubleshooting action should you perform first?

Options:

A.

Follow instructions in the Installation Guide.

B.

Follow instructions in the Maintenance Manual.

C.

Take an autodump from the system and upload to https://tuf.hds.com.

D.

Take an autodump from the system and upload to the SearchLight server.

Question 16

You need to install Hitachi Dynamic Link Manager (HDLM) on an AIX server. Which documentation provides detailed information about the supported Fibre Channel HBA drivers?

Options:

A.

HDLM HBA Guide

B.

HDLM Release Notes

C.

HDLM Concepts and Planning Guide

D.

HDLM for Windows Systems User's Guide

Question 17

A customer has virtualized both Clariion CX4 and USP V arrays in their data center behind a new HUS VM array. Within the HUS VM, they want to remove one of the virtualized LDEVs from the Clariion CX4. Which Universal Volume Manager wizard should be used?

Options:

A.

Device Manager Wizard

B.

Delete External Volumes Wizard

C.

Disconnect Third-Party Devices Wizard

D.

Edit External WWNs Wizard

Question 18

What are two ways to ensure secure access to storage through a fabric? (Choose two.)

Options:

A.

Use SNMP.

B.

Use zoning.

C.

Use Host Group security.

D.

Use port security on the switch(es).

Demo: 18 questions
Total 120 questions