Summer Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 70percent

EMC D-PE-OE-01 Dell PowerEdge Operate v2 Exam Exam Practice Test

Demo: 15 questions
Total 50 questions

Dell PowerEdge Operate v2 Exam Questions and Answers

Question 1

In order to Improve efficiency of the Data Center, the IT department has been tasked with auditing the health and performance, including any sensor alerts, for all Dell servers from the past quarter. Which two basic actions must be taken on the servers in order to obtain the requested information?

Options:

A.

Apply iDRAC Enterprise License

B.

Acquire appropriate Login privilege

C.

Set iDRAC networking to use DHCP

D.

Enable RACADM

Question 2

After adding a GPU to a Dell PowerEdge server:

• The operating system does not detect the GPU.

• Lifecycle Controller (LCC) Diagnostics reports a POST failure.

• IDRAC System Event Log shows a GPU power-related error.

What action should be performed first for practical troubleshooting?

Options:

A.

Reset the iDRAC network configuration.

B.

Modify the BIOS Thermal Profile.

C.

Reinstall the GPU driver.

D.

Reseat the GPU in its PCIe slot.

Question 3

You are managing a PowerEdge R570 and iDRAC is not reachable on the Network. You need to collect iDRAC details on the server. Which two tools will allow you to get the iDRAC details?

Options:

A.

Use RACADM to capture inventory and log

B.

Use iSM to capture inventory and log

C.

Use Lifecycle Controller to capture inventory and log

D.

Use OME to capture inventory and log

Question 4

You are in a dark site with a PowerEdge server that shows an amber light. iDRAC Is not configured for network access but the OS is installed and has RACADM for access to the iDRAC card. What RACADM command can be used to help identify the cause of the amber light?

Options:

A.

getsel

B.

getssninfo

C.

getsysinfo

D.

get led

Question 5

A technician In Portland, Oregon has been asked to update the firmware on a server in Omaha, Nebraska. They will use an NFS server also located in Nebraska for serving patches that have been vetted by their security teams. What two pieces of information does the technician need in order to access the NFS patch server from the Lifecycle Controller or iDRAC?

Options:

A.

Client IP address

B.

CHAP authentication credentials

C.

Share name

D.

Username and password

Question 6

A technician receives a new server with five drives. They need to configure the drives based on the following requirements received from the administrator:

• Drive 0 as a single disk with no RAID

• Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5

The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set.

How should the technician configure the drives?

Options:

A.

Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare

B.

Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare

C.

Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare

D.

Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare

Question 7

An administrator wants to ensure continuous visibility into the hardware health of a Dell PowerEdge server and be notified immediately if a component begins to fail. Using iDRAC, what action should be taken to meet these requirements?

Options:

A.

Monitor hardware health only through the operating system tools

B.

Log in to iDRAC only after the operating system reports a failure

C.

Configure iDRAC hardware health monitoring with automated alerting

D.

Disable system alerts to reduce unnecessary notifications

Question 8

A PowerEdge server running a virtualization workload shows CPU throttling under load, despite sufficient PSU capacity and no hardware faults. Which configuration is the cause of this issue?

Options:

A.

BIOS System Profile set to Performance per Watt

B.

iDRAC NIC set to shared mode

C.

Hyper-Threading enabled

D.

RAID controller cache set to Write-Through

Question 9

A PowerEdge R760 powers on with no video output. You decide to perform a Minimum-to-POST test. Which configuration correctly represents a valid Minimum-to-POST?

Options:

A.

One CPU with all associated DIMM, one PSU, no PCIe card

B.

One CPU, one DIMM in the primary channel, one PSU, no PCIe card

C.

Two CPUs installed with all DIMMs populated, one PCIe card

D.

One CPU with all associated DIMM, one PSU, one PCIe card

Question 10

Support has requested a SupportAssist Collection to troubleshoot memory Issues with a PowerEdge R770 server. The server is in a co-location data center with limited hours of onsite access. Which three locations are supported to export a SupportAssist Collection for gathering a full health check on a PowerEdge server?

Options:

A.

Local Storage

B.

CIFS Share

C.

SAN Storage

D.

S3 Storage

E.

NFS Storage

Question 11

You are asked to perform a quick health check across multiple NVIDIA GPUs in a cluster without impacting running workloads. Which DCGM diagnostic level should be used?

Options:

A.

Level 1

B.

Level 2

C.

Level 3

D.

Level 4

Question 12

A system administrator is tasked with upgrading the environment to VMware vSphere 8 and manage the latest Dell PowerEdge servers. The company wants to simplify operations, reduce costs, and avoid using multiple tools for physical and virtual infrastructure management. Which integration should the administrator implement to meet these requirements?

Options:

A.

Use standalone OpenManage Server Administrator

B.

Continue using OMIW for VMware integration

C.

Deploy OpenManage Enterprise with VMware vCenter

D.

Implement manual firmware updates and health checks

Question 13

An Administrator wants to change the PSU configuration In such a way that it can be redundant and can set PSU1 as the primary. What redundancy policy should the administrator select?

Options:

A.

Redundant

B.

PSU2 Redundant

C.

A/B Redundant

D.

PSU1 Redundant

Question 14

An engineer needs to install an OS that is not supported by the Lifecycle Controller on a Dell PowerEdge server. Since the OS Deployment menu cannot be used, the engineer plans to proceed with a manual installation. Which two factors should be considered in this situation?

Options:

A.

Appropriate drivers based on storage configuration must be applied.

B.

Required drivers are manually managed during installation.

C.

Hardware compatibility with the OS must be verified before installation.

D.

Firmware and driver version compatibility is checked after installation.

Question 15

On a Dell PowerEdge 16G server, iDRAC is configured to use a shared LOM port. What happens if the Auto-Dedicated NIC option is enabled and a dedicated NIC becomes available?

Options:

A.

iDRAC uses both the shared LOM and dedicated NIC simultaneously for redundancy

B.

iDRAC automatically switches to the dedicated NIC without requiring a reboot

C.

iDRAC disables network connectivity until manually reconfigured

D.

iDRAC continues using the shared LOM port until the next reboot

Demo: 15 questions
Total 50 questions